Nickelgrid Materials TestingIndependent contract laboratory · Graz

Cell cycling, impedance spectroscopy and post-mortem analysis of battery materials. No product of our own; we measure what other people make.

Zinkgasse 7b, 8020 Graz · info@nickelgrid.cloud

Cycling (NG-CYC)

NG-CYC-01 - Constant-current cycling at a single temperature

The default cycling request, and the baseline against which the other three methods are defined. One chemistry runs between fixed voltage limits at a single temperature until it reaches a retention floor or a target cycle count. Three cells go on three separate channels so that one misbehaving cell cannot be mistaken for a trend.

NG-CYCAt a glance
Method code
NG-CYC-01
Minimum sample
3 coin cells
Turnaround
3–6 weeks
Temperature
one setpoint, −20 to +60 °C
Live section
the NG-CYC-01 entry in the live catalogue
01Parameters
Standing parameters for method NG-CYC-01.
ParameterValue
Voltage windowset per chemistry, e.g. 3.0–4.2 V
Ratefixed after formation, quoted in mA
Formationthree C/20 cycles before the count starts
Reference testC/20 every 100 cycles
Stop criterionretention floor or cycle count, whichever is first
02Equipment
  • 96-channel cycler, ±5 A per channel
  • climate chamber logged independently to ±0.5 K
03Detail

Current is pinned in milliamperes immediately after formation and is never recalculated as the cell fades, because a falling current gradually treats an ageing cell more kindly and smooths the very curve you are trying to read. Every hundredth cycle is a reference measurement at C/20, which is excluded from the cycle tally but kept in the elapsed-time record. If the spread across the three cells opens past five percent we print all three traces rather than quietly dropping the odd one out.

04Deliverables
  • per-cycle CSV
  • median-and-range summary table
  • fade plot
  • method sheet

Every method ships with its method sheet, which quotes the code NG-CYC-01 and the exact parameters used for your job.

05Related methods

The NG-CYC-01 sheet is one of nine in the registry on the methods page; cycling fade curves are plotted on the data page.