Cycling (NG-CYC)
NG-CYC-04 - Lifetime matrix across four temperatures
Twelve cells from one batch are split into four temperature groups and run side by side, so that the effect of temperature is read from a single coating rather than four. Each group is three cells and reports as a median with its range. The product is the family of fade curves and the cycle number at which each one crosses the eighty-percent line.
- Method code
- NG-CYC-04
- Minimum sample
- 12 cells
- Turnaround
- 8–14 weeks
- Temperature
- four setpoints in parallel
- Live section
- the NG-CYC-04 entry in the live catalogue
| Parameter | Value |
|---|---|
| Groups | four temperatures, three cells each |
| Window | common to all groups |
| Rate | common C-rate, fixed after formation |
| Reference test | C/20 every 100 cycles |
| Stop criterion | 80 % retention or an agreed cycle ceiling |
- four chambers running concurrently
- 12 channels committed for the duration
Running the groups at the same time, rather than one after another, removes the slow drift that creeps in when a coating waits on a shelf for three months between runs. A cold group tends to lose capacity early and then level off while a hot group keeps losing it, so the curves often cross and the ranking at cycle fifty is not the ranking at cycle five hundred. We name the exact cross-over cycle instead of rounding to the nearest reference test, because a group that crosses at six hundred and ninety is not the seven hundred a rounded line would claim.
- four fade curves, each a median of three
- per-cycle CSV for every cell
- cross-over table against the 80 % line
- method sheet
Every method ships with its method sheet, which quotes the code NG-CYC-04 and the exact parameters used for your job.
The NG-CYC-04 sheet is one of nine in the registry on the methods page; cycling fade curves are plotted on the data page.