Impedance (NG-EIS)
NG-EIS-05 - Intermittent titration for diffusion coefficients
A pulse-and-rest technique that converts a staircase of small current steps into an apparent diffusion coefficient across the whole state-of-charge window. Each pulse moves a known quantity of charge, and the voltage relaxation that follows carries the kinetics. The word apparent is load-bearing, and it stays in every line of the result.
- Method code
- NG-EIS-05
- Minimum sample
- 2 cells
- Turnaround
- 9 working days
- Temperature
- one setpoint
- Live section
- the NG-EIS-05 entry in the live catalogue
| Parameter | Value |
|---|---|
| Pulse | a short current step, an agreed fraction of capacity |
| Rest | relaxation toward equilibrium between pulses |
| Coverage | across the state-of-charge window |
| Derived | apparent diffusion coefficient versus state of charge |
- cycler for the current pulses
- impedance station for the rest periods
The coefficient this method returns rests on assumptions about particle geometry that are rarely exactly true, so we present it as a curve against state of charge and let the shape, not the absolute value, carry the argument. Rest periods are set long enough that the cell is close to equilibrium before the next pulse, since a pulse applied to a still-relaxing cell poisons the following point. The technique is slow for exactly the reason the rests are long, which is why nine days is a floor and not a backlog.
- voltage-relaxation traces
- diffusion coefficient versus state of charge
- method sheet
Every method ships with its method sheet, which quotes the code NG-EIS-05 and the exact parameters used for your job.
The NG-EIS-05 sheet is one of nine in the registry on the methods page; cycling fade curves are plotted on the data page.