Cycling (NG-CYC)

NG-CYC-02 - Rate capability from C/10 to 5C

A short test that asks how much capacity survives when the current climbs. The cell steps up a fixed ladder of rates, five cycles at each, and the discharge capacity at every step is normalised to the slow-rate value. A closing slow step repeats the first, so that any permanent loss caused by the fast steps is visible instead of hidden.

NG-CYCAt a glance
Method code
NG-CYC-02
Minimum sample
3 coin cells
Turnaround
9 working days
Temperature
single, usually 25 °C
Live section
the NG-CYC-02 entry in the live catalogue
01Parameters
Standing parameters for method NG-CYC-02.
ParameterValue
Rate ladderC/10, C/5, C/2, 1C, 2C, 3C, 5C
Cycles per stepfive, the last three averaged
Recovery stepa closing C/10 that repeats the first
Windowas agreed per chemistry
02Equipment
  • 96-channel cycler
  • chamber held at the test temperature
03Detail

Rate work is quick and therefore tempting to over-read; the figure that matters is the retained fraction at the rate your application actually uses, not the headline number at 5C that most datasheets print. We report the absolute capacity at each step alongside the fraction, because a cell with a flattering fraction and a poor absolute capacity is not the bargain the fraction implies. The ladder is run once upward rather than up and down, since the downward leg mostly re-measures the recovery step.

04Deliverables
  • capacity-versus-rate table
  • retained-fraction plot
  • method sheet

Every method ships with its method sheet, which quotes the code NG-CYC-02 and the exact parameters used for your job.