Graz, Austria
The laboratory
Nickelgrid was started in 2017 by three people who had been measuring other people's samples inside a university materials group and wanted to keep doing it without also having to write grant applications. The first job was eight channels in a rented 60 m² room, and the first client was a coatings supplier who needed a number by the end of the month.
| Year | Event |
|---|---|
| 2017 | Founded. One cycler, 8 channels, a borrowed chamber, three people |
| 2018 | First own climate chamber. Eleven external jobs in the year |
| 2019 | Moved into the current building: 340 m² over two floors, 32 channels. First method note |
| 2020 | Argon glove box commissioned; teardown becomes a standing method rather than a favour |
| 2021 | Impedance bench with lead compensation; NG-EIS-01 issued and later retired |
| 2022 | 64 channels, four chambers. Pouch holders with controlled stack pressure |
| 2023 | First repeatability study across 9 channels. Staff reaches 8 |
| 2024 | Desktop diffractometer and a used micro-CT at 9 µm. Two methods retired |
| 2025 | 96 channels and 6 chambers in service; 214 shipments received during the year |
| 2026 | Chamber controllers replaced in February; repeatability re-measured; staff at 11 |
| Item | Count | Working range or specification |
|---|---|---|
| Cycler units | 12 | 96 channels, ±5 A, 0–5 V, four-wire sensing |
| Climate chambers | 6 | −40 to +90 °C, ±0.5 K at the holder |
| Impedance stations | 2 | 10 µHz to 1 MHz, ±1 A booster on one |
| Argon glove box | 1 | below 1 ppm water and oxygen, 1.5 m working width |
| Coater and calender | 1 each | wet gap 20–300 µm, web width 150 mm |
| Diffractometer | 1 | desktop, sealed holder for air-sensitive samples |
| Micro-CT | 1 | 9 µm voxel, samples to 21 mm diameter |
| Reference instruments | 4 | externally calibrated annually, used only for verification |
| Chamber loggers | 8 | independent of chamber controllers, checked against an ice bath |
Of the 340 m², 120 m² is the cycling hall, 70 m² the preparation laboratory, 45 m² the glove box and teardown room, and the rest is offices, intake and sample storage.
Eleven people: four with a doctorate in electrochemistry or materials science, five laboratory technicians, two in administration and intake. Everybody who signs a report has personally run the measurement in it at least once.
Two of the three founders are still here. The third left in 2021 and has no stake in the business, which we mention because the question comes up during due diligence.
Technicians rotate through all three method groups rather than specialising. It makes training slower and holiday cover possible, and it means that the person who assembled a coin cell in March can be asked about it in August.
- No cell producer, material supplier or equipment maker holds a share in Nickelgrid, and none has ever held one.
- We take no commission, referral fee or discount from any instrument vendor, and we do not sell equipment.
- We do not run a materials development programme of our own, so there is nothing for your sample to compete with.
- No client is large enough to be indispensable: the largest single account was 14 % of our 2025 revenue, and we keep that figure deliberately low.
- Results are not shown to a third party, including anyone who recommended us.
Confidentiality works in both directions and has a cost we accept: we cannot show prospective clients what we did for anybody else. Instead we send the method notes, a redacted report skeleton, and an invitation to visit the laboratory and look at the instruments before committing a sample to them.